What Vertiv makes for data centers
public · HQ Westerville, United States · vertiv.com
Vertiv makes power and thermal management equipment for data centers, including Liebert-brand UPS systems, rack power distribution units, CRAH units, and coolant distribution units and rack manifolds for direct-to-chip liquid cooling. It also supplies switchgear and busway through its E+I Engineering and Anord Mardix units, prefabricated modular power and cooling skids (SmartMod), and DCIM software (Environet, Trellis).
Parts, by layer
Layer 4 — Servers, racks & integration
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Power shelves & PSUs | manufacturer | inferred | AcBel, Advanced Energy/Artesyn, Bel Fuse, Chicony Power, Cosel, Delta Electronics | |
| Rack PDUs | manufacturer | inferred | Schneider Electric, Cyber Power, Delta Electronics, Eaton, Legrand, nVent | Geist |
| Enclosures | manufacturer | inferred | Schneider Electric, Eaton, Legrand, nVent, Chatsworth, Panduit |
Layer 5 — Liquid cooling (IT-side: chip to CDU)
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Direct-to-chip cold plates | manufacturer | inferred | AVC, Auras, Delta Electronics, Flex, Fositek, Foxconn (Hon Hai) | |
| Rack manifolds | manufacturer | inferred | AVC, Auras, Delta Electronics, Foxconn (Hon Hai), Kaori, Parker Hannifin | |
| Coolant distribution units | manufacturer | inferred | Auras, Daikin, Delta Electronics, Envicool, Foxconn (Hon Hai), Johnson Controls | |
| Rear-door heat exchangers | manufacturer | inferred | Legrand, nVent, Coolcentric, Huawei, Motivair, Rittal | |
| Leak detection, flow & pressure sensing | manufacturer | inferred | Schneider Electric, Emerson, Honeywell, Keyence, Sensirion, nVent | |
| Rack/row cooling controls & software | manufacturer | inferred | Schneider Electric, nVent, CoolIT, Motivair |
Layer 6 — Facility cooling & HVAC
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Chillers & compressors | manufacturer | disclosed | Schneider Electric, Carrier, Daikin, Gree, Johnson Controls, LG | |
| Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors | manufacturer | inferred | Alfa Laval, Daikin, LU-VE, Modine, Munters, SPX Technologies | |
| CRAH / CRAC / fan walls / in-row units | manufacturer | disclosed | Schneider Electric, Daikin, Envicool, Johnson Controls, Kingspan, Mitsubishi Electric | Liebert |
| Building management, controls, environmental sensors | manufacturer | inferred | Schneider Electric, ABB, Carrier, Delta Electronics, Honeywell, Johnson Controls | Liebert iCOM |
Layer 7 — Electrical: power distribution (grid to rack)
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| MV switchgear, E-houses, power skids | manufacturer | inferred | Schneider Electric, ABB, Eaton, GE Vernova, Mitsubishi Electric, Nari | E+I Engineering; Anord Mardix |
| Busway / busbar trunking | manufacturer | inferred | Schneider Electric, ABB, Chint, Delta Electronics, Eaton, LS Electric | |
| Floor PDUs, RPPs, static transfer switches, ATS | manufacturer | inferred | Schneider Electric, ABB, Caterpillar, Cummins, Delta Electronics, Eaton | PDI |
| UPS (static, modular, rotary/DRUPS) & UPS power semis | manufacturer | disclosed | Schneider Electric, ABB, Cyber Power, Delta Electronics, Eaton, Fuji Electric | |
| Power smoothing / supercapacitors | manufacturer | inferred | Delta Electronics, Eaton, Skeleton Technologies, UCAP Power | |
| Metering, power quality, monitoring | manufacturer | inferred | Schneider Electric, ABB, Eaton, Legrand, Siemens, Accuenergy | |
| 800 V DC architecture & solid-state transformers | manufacturer | inferred | Schneider Electric, ABB, Coherent, Delta Electronics, Eaton, Flex |
Layer 9 — Building shell, site & construction
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Prefab / modular data centers & power/cooling skids | manufacturer | disclosed | Schneider Electric, ABB, Delta Electronics, Eaton, Nucor, Powell | SmartMod; modular power |
Layer 11 — Software, tools & services touching the hardware (optional)
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| DCIM, digital twins, capacity planning | service | inferred | Schneider Electric, Autodesk, Bentley, Cadence, Carrier, Nvidia | Environet; Trellis |
Where Vertiv sits in the stack
Vertiv's placements in this catalog cover 22 parts, from layer 4 (servers, racks & integration) to layer 11 (software, tools & services touching the hardware (optional)). None of them currently carries a sourced supply constraint tag. Across these parts it overlaps with other companies most often on the lines below.
What these parts are
- DCIM, digital twins, capacity planning — Software that models a data center's power, cooling, space, and asset capacity in a live digital twin, giving operators visibility into what a facility can still support.
- Power shelves & PSUs — The rack-mounted power shelves that convert facility AC or DC input into the regulated rail distributed to trays across the rack, built to the Open Rack V3 33 kW-class spec used in rack-scale AI systems.
- Enclosures — The rack cabinet frame itself — the enclosure that chassis and trays mount into, sold either as a standalone product or built in-house by the rack ODM.
- Rack PDUs — The power distribution units mounted in or beside a rack that meter and distribute power to individual devices, sitting between facility power and the rack's internal busbar or whips.
- Direct-to-chip cold plates — A metal plate with internal microchannels, bonded or clamped directly onto a GPU, CPU, or switch package, that carries coolant across the die to remove heat by conduction rather than airflow.
- and 17 more in the table above.
Closest peers in this catalog
| Company | Shared parts | Including | |
|---|---|---|---|
| Schneider Electric | 15 | DCIM, digital twins, capacity planning, Enclosures, Rack PDUs and 12 more | Compare → |
| Delta Electronics | 12 | Power shelves & PSUs, Rack PDUs, Direct-to-chip cold plates and 9 more | Compare → |
| Eaton | 11 | Power shelves & PSUs, Enclosures, Rack PDUs and 8 more | Compare → |
| ABB | 8 | Building management, controls, environmental sensors, MV switchgear, E-houses, power skids, Busway / busbar trunking and 5 more | Compare → |
| nVent | 7 | Enclosures, Rack PDUs, Rack manifolds and 4 more | Compare → |
| Legrand | 6 | Enclosures, Rack PDUs, Rear-door heat exchangers and 3 more | Compare → |
Seen in real machines
Vertiv is named in 2 of the rack teardowns and supercomputer breakdowns on this site. Each line below is a piece of that machine.
- Nvidia GB300 NVL72 · rack teardown
- Rack manifolds
- CDU (in-rack or in-row)
- Rack PDU and power whips
- Leonardo · supercomputer
- Data hall UPS (four branches of 2 x 1 MW Vertiv Trinergy units with lithium batteries) (Trinergy UPS units; CINECA's slide labels the installation "Vertiv UPS System")
From the blog
Latest feed
- Vertiv expands data center kit manufacturing capacity in Slovakia — Data Center Dynamics, 2026-09-28Vertiv will increase the capacity of its power and cooling manufacturing facility in Slovakia by adding 22,000 square meters.
- Vertiv to acquire data center fluid management firm King Environmental Services — Data Center Dynamics, 2026-09-25Vertiv is acquiring King Environmental Services, a firm that specializes in data center fluid management.
- Vertiv to Buy King Environmental Services to Bolster Data Center Cooling — HPCwire, 2026-09-24Vertiv announced plans to acquire King Environmental Services to expand its global thermal management services, particularly for liquid-cooled data centers.
- SGC Energy partners with Vertiv to deploy PowerNexus at planned AI data center in Gunsan, South Korea — Data Center Dynamics, 2026-09-08SGC Energy and Vertiv plan to deploy a PowerNexus system for a future AI data center in South Korea.
- Vertiv acquires microgrid company UtilityInnovation — Data Center Dynamics, 2026-09-03Vertiv acquired UtilityInnovation, a move positioning the company higher up in the data center's power infrastructure supply chain.
Questions about Vertiv
- What does Vertiv make for AI data centers?
- This catalog places Vertiv on 22 parts: Power shelves & PSUs (manufacturer), Rack PDUs (manufacturer), Direct-to-chip cold plates (manufacturer), Rack manifolds (manufacturer), Coolant distribution units (manufacturer), Rear-door heat exchangers (manufacturer), Leak detection, flow & pressure sensing (manufacturer) and Rack/row cooling controls & software (manufacturer), and 14 more.
- Is Vertiv publicly traded?
- Yes — Vertiv is listed on US exchanges (NYSE/Nasdaq) under VRT. Prices shown on this page are a nightly snapshot, not real-time, and nothing here is investment advice.
- Where is Vertiv based?
- Westerville, United States, per the company record in this catalog.
- Who else makes power shelves & PSUs for AI data centers?
- AcBel, Advanced Energy/Artesyn, Bel Fuse, Chicony Power, Cosel and Delta Electronics are also placed on Power shelves & PSUs in this catalog.
- How well sourced are these placements?
- Every part→company placement carries a confidence tag. For Vertiv the mix is 4 disclosed and 18 inferred. "disclosed" means the company or a filing says so; "reported" comes from trade press or a reference-design list; "inferred" is a lead from the taxonomy with no citation yet. Treat reported and inferred as leads, not facts.
Answers are generated from this catalog's own rows — see sources & method.
Verification: enriched, last verified 2026-08-27. Sources: www.vertiv.com · en.wikipedia.org.· Markdown · JSON