Layer 5 — Liquid cooling (IT-side: chip to CDU)
Position in the die→grid hierarchy: the rack.
Liquid cooling on the IT side, from the chip to the coolant distribution unit: cold plates, manifolds, quick disconnects, hoses, CDUs, the pumps and plate heat exchangers inside them, the fluids in the loop, and the sensors watching for leaks.
Layer 5 covers everything that moves heat off an AI accelerator and out to the coolant distribution unit (CDU) — the IT-side half of a liquid-cooling loop, before the heat is handed to the facility water loop in Layer 6. The chain runs from cold plates bonded to the GPU, CPU, and switch packages, through rack manifolds and quick disconnects, hoses and fittings, up to the CDU itself and the plate heat exchangers, pumps, and filters inside it. Rear-door heat exchangers and immersion systems are alternate architectures that skip or reshape parts of that chain. Fluids and coolant treatment, leak detection and sensing, and rack/row controls run alongside the physical loop and keep it safe and tuned. Air cooling could not keep pace with GPU power density, so this layer went from a niche add-on to a default rack component in a few product cycles. The investable choke points sit at the connection points rather than the pipe itself: quick disconnects and cold plates require tight tolerances and qualification against a specific chip package, so switching suppliers mid-program is costly; CDUs bundle mechanical, thermal, and controls engineering that not every player can scale to facility-class units; and the reference-design ODMs (Foxconn, Wiwynn) building cold plates in-house for their own racks compete directly with the component vendors this layer otherwise depends on. Fluids sit downstream of a real supply shift, with a large single-phase and two-phase producer exiting part of the category.
Parts in this layer
- 5.01 Direct-to-chip cold plates · 21 companiesA metal plate with internal microchannels, bonded or clamped directly onto a GPU, CPU, or switch package, that carries coolant across the die to remove heat by conduction rather than airflow.
- 5.02 Rack manifolds (CDMs) · 11 companiesThe manifold (sometimes called a CDM) that distributes coolant from the CDU supply line to each cold plate in a rack and collects the return flow, usually mounted vertically at the rear or side of the rack.
- 5.03 Quick disconnects (UQD / UQDB) · 7 companiesBlind-mate connectors (UQD or UQDB) that let a compute tray or cold plate be connected to or disconnected from the coolant manifold without draining or spilling the loop.
- 5.04 Hoses, tubing, fittings, valves · 9 companiesThe flexible hoses, rigid tubing, compression and push-fit fittings, and shutoff or balancing valves that carry coolant between manifolds, quick disconnects, and the CDU.
- 5.05 Coolant distribution units (in-rack, in-row, 1–2.5 MW+ facility units) · 24 companiesThe unit that separates the IT-side (technology) coolant loop from the facility water loop, exchanging heat between them and pumping and filtering the technology-side flow — sized from in-rack and in-row units up to multi-megawatt facility-class units.
- 5.06 CDU internals: plate heat exchangers, pumps, filters · 13 companiesThe internal components of a CDU — plate heat exchangers, pumps, and filters — that do the actual heat exchange, circulation, and particulate control inside the unit.
- 5.07 Rear-door heat exchangers · 8 companiesA heat exchanger mounted on the rear door of a server rack that cools exhaust air with chilled water or refrigerant before it leaves the rack, without cooling the chips directly.
- 5.08 Immersion cooling systems · 9 companiesSystems that submerge servers or trays directly in a dielectric fluid, either in open tanks (single-phase) or sealed chambers where the fluid boils and recondenses (two-phase), to cool the whole tray rather than individual dies.
- 5.09 Fluids & coolant treatment · 16 companiesThe coolant fluids that circulate through direct-to-chip and immersion loops, plus the chemical treatment (inhibitors, biocides) that keeps them stable over the life of the loop.
- 5.10 Leak detection, flow & pressure sensing · 10 companiesSensors and systems that detect coolant leaks and monitor flow rate and pressure throughout the liquid-cooling loop, feeding alerts to rack and row controls.
- 5.11 Rack/row cooling controls & software · 5 companiesSoftware and controllers that manage coolant setpoints, pump speed, and valve positions at the rack and row level, and that tie into facility-wide data center infrastructure management (DCIM) systems.
Public plays in this layer
Listed companies with the most part placements in layer 5. Placement count is breadth, not revenue exposure.
| Company | Ticker | Parts here | Price | Mkt cap |
|---|---|---|---|---|
| Vertiv | VRT | 6 | 269 USD | 103.7B |
| nVent | NVT | 5 | 156 USD | 25.2B |
| Parker Hannifin | PH | 4 | 1011 USD | 127.5B |
| Kaori | 8996.TW | 4 | 1270 TWD | 118.1B |
| Foxconn (Hon Hai) | 2317.TW | 3 | 253 TWD | 3.54T |
| Eaton | ETN | 3 | 416 USD | 161.5B |
| Delta Electronics | 2308.TW | 3 | 1800 TWD | 4.68T |
| Auras | 3324.TWO | 3 | 1125 TWD | 104.7B |
| Shell | SHEL | 2 | 90.70 USD | 249.6B |
| Schneider Electric | SU.PA | 2 | 298 EUR | 167.2B |
| Nidec | 6594.T | 2 | 2620 JPY | 3.00T |
| Fositek | 6805.TW | 2 | 2355 TWD | 161.4B |
| Emerson | EMR | 2 | 158 USD | 88.0B |
| AVC | 3017.TW | 2 | 3405 TWD | 1.34T |
| Xylem | XYL | 1 | 113 USD | 26.3B |
| Wiwynn | 6669.TW | 1 | 7020 TWD | 3.91T |
| Trane | TT | 1 | 454 USD | 100.0B |
| Supermicro | SMCI | 1 | 38.46 USD | 24.9B |
| Sensirion | SENS.SW | 1 | 83.70 CHF | 1.3B |
| Munters | MTRS.ST | 1 | 169 SEK | 30.8B |
| Mitsubishi Electric | 6503.T | 1 | 5641 JPY | 11.54T |
| LyondellBasell | LYB | 1 | 63.06 USD | 20.4B |
| Lotes | 3533.TW | 1 | 1650 TWD | 187.7B |
| Legrand | LR.PA | 1 | 136 EUR | 35.8B |
| Kurita | 6370.T | 1 | 8146 JPY | 877.3B |