Who makes immersion cooling systems for AI data centers

Systems that submerge servers or trays directly in a dielectric fluid, either in open tanks (single-phase) or sealed chambers where the fluid boils and recondenses (two-phase), to cool the whole tray rather than individual dies.

Immersion cooling replaces the cold-plate-and-manifold chain entirely: instead of routing coolant to each die through a plate, the whole server tray sits in a bath of dielectric fluid that carries heat away by direct contact. Single-phase systems keep the fluid liquid throughout and rely on pumps and heat exchangers to move heat out of the tank; two-phase systems let the fluid boil at the hot surfaces and recondense at a coil, using the phase change itself to move heat more efficiently. It is a different mechanical and facility design from the rack-based direct-to-chip chain used elsewhere in this layer — servers and racks built for immersion need different chassis, connectors, and serviceability approaches, and retrofitting an existing air-cooled or direct-to-chip hall for immersion is a bigger undertaking than adding cold plates. Adoption has concentrated in specific use cases rather than becoming the default alongside direct-to-chip. Investors should watch it as a higher-conviction, narrower bet than direct-to-chip cooling: fewer vendors, less standardization, and adoption tied to specific operators and use cases rather than broad industry uptake.

Appears at:Enterprise / small coloLarge colo / hyperscale buildingAI campus· cooling:liquid — Deployment depends on a design choice to build for immersion rather than direct-to-chip; where used, tank or chamber count scales with server count rather than facility power tier.

Companies on this part (9)

CompanyRoleOwnershipTickerPrice1dConfidenceNote
Asperitasmanufacturerprivateinferred
Firmus (Sustainable Metal Cloud)manufacturerprivateinferred
GRCmanufacturerprivateinferred
Hypertecmanufacturerprivateinferred
Iceotopemanufacturerprivateinferred
LiquidStackmanufacturerprivateinferred
Midasmanufacturerprivateinferred
Submermanufacturerprivateinferred
TMGcoremanufacturerprivateinferred

Who competes here

The same table read the other way: every company above competes for immersion cooling systems sockets. Confidence tags matter — an inferred placement is a lead, not a confirmed rivalry.

Nearby parts

Watch

Immersion Cooling Explained
MEP Academy — single- vs two-phase immersion cooling fundamentals
Click to load from YouTube · open on YouTube ↗

Independent videos — no affiliation; nothing loads from YouTube until you click.

Sources: placements without a source URL come from the taxonomy seed and are tagged accordingly. How this data is builtMarkdown · JSON