Who makes rear-door heat exchangers for AI data centers
A heat exchanger mounted on the rear door of a server rack that cools exhaust air with chilled water or refrigerant before it leaves the rack, without cooling the chips directly.
The rear-door heat exchanger is an air-assist approach rather than a direct-to-chip one: it sits behind a rack of otherwise air-cooled servers and pulls heat out of the exhaust air using a chilled-water or refrigerant coil before that air re-enters the room, rather than cooling the die directly the way a cold plate does. It is typically deployed where a facility wants to raise the density it can support without redesigning every server for direct liquid cooling, or as a supplement in racks that mix liquid-cooled accelerators with air-cooled networking and storage. Because it works at the rack-exhaust level rather than the die level, it has a lower cooling ceiling than a direct-to-chip loop and is generally positioned as a bridge or hybrid option rather than the primary cooling path for the highest-density AI racks. Investors should watch it as a hybrid-density play: demand depends on how much of the installed base stays on air or mixed cooling rather than converting fully to direct-to-chip.
Companies on this part (8)
| Company | Role | Ownership | Ticker | Price | 1d | Confidence | Note |
|---|---|---|---|---|---|---|---|
| Legrand | manufacturer | public | LR.PA | 136 EUR | -0.8% | inferred | |
| Motivair · unit of Schneider Electric | manufacturer | subsidiary | SU.PA* | inferred | |||
| nVent | manufacturer | public | NVT | 156 USD | -1.5% | inferred | |
| Vertiv | manufacturer | public | VRT | 269 USD | -1.5% | inferred | |
| Coolcentric | manufacturer | private | inferred | ||||
| Huawei | manufacturer | private | inferred | ||||
| Rittal | manufacturer | private | inferred | ||||
| Stulz | manufacturer | private | inferred |
Who competes here
The same table read the other way: every company above competes for rear-door heat exchangers sockets. Confidence tags matter — an inferred placement is a lead, not a confirmed rivalry.
Nearby parts
- Previous in layer: CDU internals: plate heat exchangers, pumps, filters
- Next in layer: Immersion cooling systems
- Layer: Layer 5 — Liquid cooling (IT-side: chip to CDU)