What Rittal makes for data centers
private · HQ Herborn, Germany · rittal.com
Ownership: Friedhelm Loh Group (private)
Rittal makes enclosure and rack systems, power distribution, and climate-control equipment including CDUs for IT and data-center use, along with modular data-center designs. It is the largest company in the privately owned Friedhelm Loh Group.
Parts, by layer
Layer 4 — Servers, racks & integration
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Rack PDUs | manufacturer | inferred | Schneider Electric, Cyber Power, Delta Electronics, Eaton, Legrand, Vertiv | |
| Enclosures | manufacturer | inferred | Schneider Electric, Eaton, Legrand, Vertiv, nVent, Chatsworth |
Layer 5 — Liquid cooling (IT-side: chip to CDU)
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Coolant distribution units | manufacturer | inferred | Auras, Daikin, Delta Electronics, Envicool, Foxconn (Hon Hai), Johnson Controls | |
| Rear-door heat exchangers | manufacturer | inferred | Legrand, Vertiv, nVent, Coolcentric, Huawei, Motivair |
Layer 6 — Facility cooling & HVAC
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| CRAH / CRAC / fan walls / in-row units | manufacturer | disclosed | Schneider Electric, Daikin, Envicool, Johnson Controls, Kingspan, Mitsubishi Electric |
Layer 9 — Building shell, site & construction
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Prefab / modular data centers & power/cooling skids | manufacturer | inferred | Schneider Electric, ABB, Delta Electronics, Eaton, Nucor, Powell |
Where Rittal sits in the stack
Rittal's placements in this catalog cover 6 parts, from layer 4 (servers, racks & integration) to layer 9 (building shell, site & construction). None of them currently carries a sourced supply constraint tag. Across these parts it overlaps with other companies most often on the lines below.
What these parts are
- Enclosures — The rack cabinet frame itself — the enclosure that chassis and trays mount into, sold either as a standalone product or built in-house by the rack ODM.
- Rack PDUs — The power distribution units mounted in or beside a rack that meter and distribute power to individual devices, sitting between facility power and the rack's internal busbar or whips.
- Coolant distribution units — The unit that separates the IT-side (technology) coolant loop from the facility water loop, exchanging heat between them and pumping and filtering the technology-side flow — sized from in-rack and in-row units up to multi-megawatt facility-class units.
- Rear-door heat exchangers — A heat exchanger mounted on the rear door of a server rack that cools exhaust air with chilled water or refrigerant before it leaves the rack, without cooling the chips directly.
- CRAH / CRAC / fan walls / in-row units — CRAH, CRAC, fan-wall, and in-row units circulate conditioned air across IT equipment in air-cooled halls, using either facility chilled water (CRAH) or an internal refrigerant circuit (CRAC).
- and 1 more in the table above.
Closest peers in this catalog
Seen in real machines
Rittal is named in 2 of the rack teardowns and supercomputer breakdowns on this site. Each line below is a piece of that machine.
- Nvidia GB300 NVL72 · rack teardown
- Rack cabinet, rails, chassis
- Doudna (NERSC-10) · supercomputer
- Early-access system Cech (72 Grace CPUs, 144 Blackwell GPUs, Quantum-X800 InfiniBand; Dell IR7000-series direct-liquid-cooled rack with an in-row coolant distribution unit and rear-door heat exchanger) (in-row V3.5 coolant distribution unit, the first U.S. deployment of that model)
Questions about Rittal
- What does Rittal make for AI data centers?
- This catalog places Rittal on 6 parts: Rack PDUs (manufacturer), Coolant distribution units (manufacturer), Rear-door heat exchangers (manufacturer), CRAH / CRAC / fan walls / in-row units (manufacturer), Prefab / modular data centers & power/cooling skids (manufacturer) and Enclosures (manufacturer).
- Is Rittal publicly traded?
- No listing is on file for Rittal in this catalog; it is recorded as private.
- Where is Rittal based?
- Herborn, Germany, per the company record in this catalog.
- Who else makes rack PDUs for AI data centers?
- Schneider Electric, Cyber Power, Delta Electronics, Eaton, Legrand and Vertiv are also placed on Rack PDUs in this catalog.
- How well sourced are these placements?
- Every part→company placement carries a confidence tag. For Rittal the mix is 1 disclosed and 5 inferred. "disclosed" means the company or a filing says so; "reported" comes from trade press or a reference-design list; "inferred" is a lead from the taxonomy with no citation yet. Treat reported and inferred as leads, not facts.