Who makes coolant distribution units for AI data centers

Coolant distribution units (in-rack, in-row, 1–2.5 MW+ facility units)

The unit that separates the IT-side (technology) coolant loop from the facility water loop, exchanging heat between them and pumping and filtering the technology-side flow — sized from in-rack and in-row units up to multi-megawatt facility-class units.

The CDU is the boundary of Layer 5: everything upstream (cold plates, manifolds, quick disconnects, hoses) is the technology-side loop it feeds, and everything downstream (chillers, cooling towers, the facility water loop) belongs to Layer 6. Inside, a plate heat exchanger keeps the clean, controlled technology-side coolant physically separate from facility water, while pumps circulate the technology-side flow and filters protect the cold plates from particulates. CDUs come in three form factors — in-rack units serving a single rack, in-row units serving several racks, and facility-class units in the 1–2.5 MW-plus range serving a whole row or hall — and the choice among them is a design decision driven by rack density and facility layout rather than a strict scale progression. As GPU racks moved from air to liquid cooling, CDU capacity requirements rose sharply, and controls (temperature setpoints, redundant pumps, leak response) became as important as the mechanical design. Investors should watch which vendors can scale from smaller in-rack or in-row units to facility-class CDUs, since that is a different engineering and manufacturing problem, and note that some server integrators build CDUs in-house for their own rack designs.

AI delta: The shift of AI accelerator racks from air to liquid cooling pushed CDU capacity requirements up sharply and pulled facility-class (1–2.5 MW-plus) units into more deployments alongside smaller in-rack and in-row units.

Appears at:Enterprise / small coloLarge colo / hyperscale buildingAI campusGW-class campus· cooling:liquidhybrid — Form factor is a design choice, not a strict scale tier: in-rack and in-row units suit smaller or mixed deployments, while facility-class (1–2.5 MW-plus) units suit large, liquid-dense halls.

Companies on this part (24)

CompanyRoleOwnershipTickerPrice1dConfidenceNote
Airedale · unit of ModinemanufacturersubsidiaryMOD*inferred
Aurasmanufacturerpublic3324.TWO1125 TWD+6.1%inferred
Daikinmanufacturerpublic6367.T20900 JPY+0.0%inferred
Delta Electronicsmanufacturerpublic2308.TW1800 TWD+2.0%inferred
Envicoolmanufacturerpublic002837.SZ66.41 CNY+0.7%inferred
Foxconn (Hon Hai)manufacturerpublic2317.TW253 TWD+0.2%inferred
Johnson ControlsmanufacturerpublicJCI142 USD-1.3%inferred
Kaorimanufacturerpublic8996.TW1270 TWD-3.1%inferred
Mitsubishi Electricmanufacturerpublic6503.T5641 JPY+1.0%reported
Motivair · unit of Schneider ElectricmanufacturersubsidiarySU.PA*inferred
MuntersmanufacturerpublicMTRS.ST169 SEK-2.7%inferred
Nidecmanufacturerpublic6594.T2620 JPY+0.2%inferred
nVentmanufacturerpublicNVT156 USD-1.5%inferred
Supermicroin housepublicSMCI38.46 USD+0.3%inferredin-house
TranemanufacturerpublicTT454 USD-2.0%inferred
VertivmanufacturerpublicVRT269 USD-1.5%inferred
Airsysmanufacturerprivateinferred
Boydmanufacturerprivateinferred
Chilldynemanufacturerprivateinferred
CoolITmanufacturerprivateinferred
Huaweimanufacturerprivateinferred
LiquidStackmanufacturerprivateinferred
Rittalmanufacturerprivateinferred
Stulzmanufacturerprivateinferred

Who competes here

The same table read the other way: every company above competes for coolant distribution units sockets. Confidence tags matter — an inferred placement is a lead, not a confirmed rivalry.

Nearby parts

Watch

Coolant Distribution Unit (CDU) for AI Data Center Cooling | Schneider Electric
Schneider Electric — CDU's role bridging facility and technology cooling loops
Click to load from YouTube · open on YouTube ↗
CDUs: Enabling the Transition From Air Cooling to Liquid Cooling