5.05

Who makes coolant distribution units for AI data centers

Coolant distribution units (in-rack, in-row, 1–2.5 MW+ facility units)

The unit that separates the IT-side (technology) coolant loop from the facility water loop, exchanging heat between them and pumping and filtering the technology-side flow — sized from in-rack and in-row units up to multi-megawatt facility-class units.

The CDU is the boundary of Layer 5: everything upstream (cold plates, manifolds, quick disconnects, hoses) is the technology-side loop it feeds, and everything downstream (chillers, cooling towers, the facility water loop) belongs to Layer 6. Inside, a plate heat exchanger keeps the clean, controlled technology-side coolant physically separate from facility water, while pumps circulate the technology-side flow and filters protect the cold plates from particulates. CDUs come in three form factors — in-rack units serving a single rack, in-row units serving several racks, and facility-class units in the 1–2.5 MW-plus range serving a whole row or hall — and the choice among them is a design decision driven by rack density and facility layout rather than a strict scale progression. As GPU racks moved from air to liquid cooling, CDU capacity requirements rose sharply, and controls (temperature setpoints, redundant pumps, leak response) became as important as the mechanical design. Investors should watch which vendors can scale from smaller in-rack or in-row units to facility-class CDUs, since that is a different engineering and manufacturing problem, and note that some server integrators build CDUs in-house for their own rack designs.

AI delta: The shift of AI accelerator racks from air to liquid cooling pushed CDU capacity requirements up sharply and pulled facility-class (1–2.5 MW-plus) units into more deployments alongside smaller in-rack and in-row units.

Appears at:Enterprise / small coloLarge colo / hyperscale buildingAI campusGW-class campus· cooling:liquidhybrid — Form factor is a design choice, not a strict scale tier: in-rack and in-row units suit smaller or mixed deployments, while facility-class (1–2.5 MW-plus) units suit large, liquid-dense halls.

Companies on this part (24)

CompanyRoleOwnershipTickerPrice1dConfidenceNote
Airedale · unit of ModinemanufacturersubsidiaryMOD*inferred
Aurasmanufacturerpublic3324.TWO1360 TWD+0.4%inferred
Daikinmanufacturerpublic6367.T21185 JPY-0.7%inferred
Delta Electronicsmanufacturerpublic2308.TW1560 TWD-3.4%inferred
Envicoolmanufacturerpublic002837.SZ44.38 CNY+1.8%inferred
Foxconn (Hon Hai)manufacturerpublic2317.TW245 TWD-1.6%inferred
Johnson ControlsmanufacturerpublicJCI144 USD+0.1%inferred
Kaorimanufacturerpublic8996.TW1560 TWD-7.4%inferred
Mitsubishi Electricmanufacturerpublic6503.T4770 JPY-2.3%reported
Motivair · unit of Schneider ElectricmanufacturersubsidiarySU.PA*inferred
MuntersmanufacturerpublicMTRS.ST131 SEK+4.0%inferred
Nidecmanufacturerpublic6594.T1705 JPY-0.5%inferred
nVentmanufacturerpublicNVT125 USD-2.4%inferred
Supermicroin housepublicSMCI32.94 USD-1.7%inferredin-house
TranemanufacturerpublicTT445 USD-0.9%inferred
VertivmanufacturerpublicVRT194 USD-0.2%inferred
Airsysmanufacturerprivateinferred
Boydmanufacturerprivateinferred
Chilldynemanufacturerprivateinferred
CoolITmanufacturerprivateinferred
Huaweimanufacturerprivateinferred
LiquidStackmanufacturerprivateinferred
Rittalmanufacturerprivateinferred
Stulzmanufacturerprivateinferred

Who competes here

The same table read the other way: every company above competes for coolant distribution units sockets. Confidence tags matter — an inferred placement is a lead, not a confirmed rivalry.

Seen in real machines

coolant distribution units is named in 9 of the rack teardowns and supercomputer breakdowns on this site. Each line below is a piece of that machine. The companies shown are the ones named on that line, not necessarily the maker of this part.

Nearby parts

From the blog

Watch

Coolant Distribution Unit (CDU) for AI Data Center Cooling | Schneider Electric
Schneider Electric — CDU's role bridging facility and technology cooling loops
Click to load from YouTube · open on YouTube ↗
CDUs: Enabling the Transition From Air Cooling to Liquid Cooling
Data Center Richness — independent explainer on why CDUs anchor liquid cooling adoption
Click to load from YouTube · open on YouTube ↗

Independent videos — no affiliation; nothing loads from YouTube until you click.

Latest feed

Questions about coolant distribution units

What are coolant distribution units?
The unit that separates the IT-side (technology) coolant loop from the facility water loop, exchanging heat between them and pumping and filtering the technology-side flow — sized from in-rack and in-row units up to multi-megawatt facility-class units.
Which companies make coolant distribution units for AI data centers?
This catalog lists 24 companies on Coolant distribution units, 16 of them with listed equity: Airedale, Auras, Daikin, Delta Electronics, Envicool, Foxconn (Hon Hai), Johnson Controls, Kaori, Mitsubishi Electric, Motivair, and 14 more.
How does AI change demand for coolant distribution units?
The shift of AI accelerator racks from air to liquid cooling pushed CDU capacity requirements up sharply and pulled facility-class (1–2.5 MW-plus) units into more deployments alongside smaller in-rack and in-row units.
How reliable are these coolant distribution units supplier placements?
The 24 placements on this part break down as 1 reported, 23 inferred. "disclosed" means the company or a filing says so; "reported" comes from trade press or a reference-design list; "inferred" is a taxonomy lead with no citation yet.

Sources: placements without a source URL come from the taxonomy seed and are tagged accordingly. How this data is built.· Markdown · JSON