Part of the day: Coolant distribution units
Assembled by the nightly build from this catalog’s own entry for Coolant distribution units (5.05, Layer 5 — Liquid cooling (IT-side: chip to CDU)). The tables below are rebuilt every night; published 2026-10-08.
The unit that separates the IT-side (technology) coolant loop from the facility water loop, exchanging heat between them and pumping and filtering the technology-side flow — sized from in-rack and in-row units up to multi-megawatt facility-class units.
The CDU is the boundary of Layer 5: everything upstream (cold plates, manifolds, quick disconnects, hoses) is the technology-side loop it feeds, and everything downstream (chillers, cooling towers, the facility water loop) belongs to Layer 6. Inside, a plate heat exchanger keeps the clean, controlled technology-side coolant physically separate from facility water, while pumps circulate the technology-side flow and filters protect the cold plates from particulates. CDUs come in three form factors — in-rack units serving a single rack, in-row units serving several racks, and facility-class units in the 1–2.5 MW-plus range serving a whole row or hall — and the choice among them is a design decision driven by rack density and facility layout rather than a strict scale progression. As GPU racks moved from air to liquid cooling, CDU capacity requirements rose sharply, and controls (temperature setpoints, redundant pumps, leak response) became as important as the mechanical design. Investors should watch which vendors can scale from smaller in-rack or in-row units to facility-class CDUs, since that is a different engineering and manufacturing problem, and note that some server integrators build CDUs in-house for their own rack designs.
AI delta: The shift of AI accelerator racks from air to liquid cooling pushed CDU capacity requirements up sharply and pulled facility-class (1–2.5 MW-plus) units into more deployments alongside smaller in-rack and in-row units.
Who makes it
| Company | Role | Ownership | Ticker | Price | 1d | Confidence | Note |
|---|---|---|---|---|---|---|---|
| Airedale · unit of Modine | manufacturer | subsidiary | MOD* | inferred | |||
| Auras | manufacturer | public | 3324.TWO | 1360 TWD | +0.4% | inferred | |
| Daikin | manufacturer | public | 6367.T | 21185 JPY | -0.7% | inferred | |
| Delta Electronics | manufacturer | public | 2308.TW | 1560 TWD | -3.4% | inferred | |
| Envicool | manufacturer | public | 002837.SZ | 44.38 CNY | +1.8% | inferred | |
| Foxconn (Hon Hai) | manufacturer | public | 2317.TW | 245 TWD | -1.6% | inferred | |
| Johnson Controls | manufacturer | public | JCI | 144 USD | +0.1% | inferred | |
| Kaori | manufacturer | public | 8996.TW | 1560 TWD | -7.4% | inferred | |
| Mitsubishi Electric | manufacturer | public | 6503.T | 4770 JPY | -2.3% | reported | |
| Motivair · unit of Schneider Electric | manufacturer | subsidiary | SU.PA* | inferred | |||
| Munters | manufacturer | public | MTRS.ST | 131 SEK | +4.0% | inferred | |
| Nidec | manufacturer | public | 6594.T | 1705 JPY | -0.5% | inferred | |
| nVent | manufacturer | public | NVT | 125 USD | -2.4% | inferred | |
| Supermicro | in house | public | SMCI | 32.94 USD | -1.7% | inferred | in-house |
| Trane | manufacturer | public | TT | 445 USD | -0.9% | inferred | |
| Vertiv | manufacturer | public | VRT | 194 USD | -0.2% | inferred | |
| Airsys | manufacturer | private | inferred | ||||
| Boyd | manufacturer | private | inferred | ||||
| Chilldyne | manufacturer | private | inferred | ||||
| CoolIT | manufacturer | private | inferred | ||||
| Huawei | manufacturer | private | inferred | ||||
| LiquidStack | manufacturer | private | inferred | ||||
| Rittal | manufacturer | private | inferred | ||||
| Stulz | manufacturer | private | inferred |
The full entry — sub-categories, news, videos and sources — lives on the Coolant distribution units page.