What Modine makes for data centers
public
Modine is a publicly listed company. It appears on 3 parts of the AI data center — Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors, Coolant distribution units and CRAH / CRAC / fan walls / in-row units — in the role of manufacturer. Those parts sit in Layer 5 — Liquid cooling (IT-side: chip to CDU) and Layer 6 — Facility cooling & HVAC. Its shares trade on US exchanges (NYSE/Nasdaq) as MOD.
Units and subsidiaries: Airedale
Parts, by layer
Layer 5 — Liquid cooling (IT-side: chip to CDU)
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Coolant distribution units (via Airedale) | manufacturer | inferred | Auras, Daikin, Delta Electronics, Envicool, Foxconn (Hon Hai), Johnson Controls |
Layer 6 — Facility cooling & HVAC
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors | manufacturer | inferred | Alfa Laval, Daikin, LU-VE, Munters, SPX Technologies, Vertiv | |
| CRAH / CRAC / fan walls / in-row units (via Airedale) | manufacturer | inferred | Schneider Electric, Daikin, Envicool, Johnson Controls, Kingspan, Mitsubishi Electric |
Where Modine sits in the stack
Modine's placements in this catalog cover 3 parts, from layer 5 (liquid cooling (it-side: chip to cdu)) to layer 6 (facility cooling & hvac). None of them currently carries a sourced supply constraint tag. Across these parts it overlaps with other companies most often on the lines below.
What these parts are
- Coolant distribution units — The unit that separates the IT-side (technology) coolant loop from the facility water loop, exchanging heat between them and pumping and filtering the technology-side flow — sized from in-rack and in-row units up to multi-megawatt facility-class units.
- Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors — Dry coolers, adiabatic/evaporative units, and cooling towers reject heat picked up by the facility water loop to outside air, driven by fans and motors.
- CRAH / CRAC / fan walls / in-row units — CRAH, CRAC, fan-wall, and in-row units circulate conditioned air across IT equipment in air-cooled halls, using either facility chilled water (CRAH) or an internal refrigerant circuit (CRAC).
Closest peers in this catalog
Questions about Modine
- What does Modine make for AI data centers?
- This catalog places Modine on 3 parts: Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors (manufacturer), Coolant distribution units (manufacturer) and CRAH / CRAC / fan walls / in-row units (manufacturer).
- Is Modine publicly traded?
- Yes — Modine is listed on US exchanges (NYSE/Nasdaq) under MOD. Prices shown on this page are a nightly snapshot, not real-time, and nothing here is investment advice.
- Who else makes dry coolers, adiabatic/evaporative units, cooling towers, fans & motors for AI data centers?
- Alfa Laval, Daikin, LU-VE, Munters, SPX Technologies and Vertiv are also placed on Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors in this catalog.
- How well sourced are these placements?
- Every part→company placement carries a confidence tag. For Modine the mix is 3 inferred. "disclosed" means the company or a filing says so; "reported" comes from trade press or a reference-design list; "inferred" is a lead from the taxonomy with no citation yet. Treat reported and inferred as leads, not facts.
Answers are generated from this catalog's own rows — see sources & method.