Who makes direct-to-chip cold plates for AI data centers
A metal plate with internal microchannels, bonded or clamped directly onto a GPU, CPU, or switch package, that carries coolant across the die to remove heat by conduction rather than airflow.
The cold plate is the first thermal interface in the loop: coolant enters through a quick disconnect, flows across channels machined or etched into the plate above the silicon, and exits carrying the heat toward the rack manifold. Every accelerator, CPU, and switch die on a liquid-cooled tray gets its own plate, so the part is qualified against a specific chip package and reference design rather than sold as a generic component. That qualification tie is the main structural feature investors should track: a plate design that wins a reference socket tends to stay for the life of that platform, and switching vendors mid-cycle means re-validating thermal performance against the die. AI GPUs run hotter and denser than prior server chips, which is why liquid cold plates displaced air heatsinks as the default rather than an option, and why two-phase and microfluidic variants are being developed for the next step up in power density. Some rack integrators build cold plates in-house for their own designs, which narrows the market available to independent cold-plate makers even as unit volume grows. Watch for supplier concentration at the top GPU platforms and how much of the volume in-house integrators keep for themselves versus outsource.
AI delta: Rising per-die power density pushed liquid cold plates from a niche option to the default thermal interface on AI accelerator packages, direct-to-chip cooling being the entry point for the two-phase and microfluidic variants under development for the next density step.
Companies on this part (15)
| Company | Role | Ownership | Ticker | Price | 1d | Confidence | Note |
|---|---|---|---|---|---|---|---|
| Auras | manufacturer | public | 3324.TWO | 1125 TWD | +6.1% | inferred | |
| AVC | manufacturer | public | 3017.TW | 3405 TWD | +2.3% | inferred | |
| Delta Electronics | manufacturer | public | 2308.TW | 1800 TWD | +2.0% | inferred | |
| Flex | manufacturer | public | FLEX | 115 USD | +1.1% | inferred | |
| Fositek | manufacturer | public | 6805.TW | 2355 TWD | +5.8% | reported | |
| Foxconn (Hon Hai) | in house | public | 2317.TW | 253 TWD | +0.2% | inferred | in-house for their own racks |
| Jentech | manufacturer | public | 3653.TW | 5810 TWD | +3.5% | inferred | |
| Kaori | manufacturer | public | 8996.TW | 1270 TWD | -3.1% | inferred | |
| Lotes | manufacturer | public | 3533.TW | 1650 TWD | +1.9% | reported | |
| Nidec | manufacturer | public | 6594.T | 2620 JPY | +0.2% | inferred | |
| Vertiv | manufacturer | public | VRT | 269 USD | -1.5% | inferred | |
| Wiwynn · unit of Wistron | in house | public | 6669.TW | 7020 TWD | +3.5% | inferred | |
| Boyd | manufacturer | private | inferred | ||||
| Cooler Master | manufacturer | private | inferred | ||||
| CoolIT | manufacturer | private | inferred |
Two-phase and microfluidic 5.01a
Who competes here
The same table read the other way: every company above competes for direct-to-chip cold plates sockets. Confidence tags matter — an inferred placement is a lead, not a confirmed rivalry.
Nearby parts
- Children: Two-phase and microfluidic
- Next in layer: Rack manifolds
- Layer: Layer 5 — Liquid cooling (IT-side: chip to CDU)
Watch
Independent videos — no affiliation; nothing loads from YouTube until you click.
Latest feed
- LG CNS deploys direct-to-chip cooling for Naver Cloud at data center in Goyang City, South Korea — Data Center Dynamics, 2026-08-27LG CNS implemented direct-to-chip cooling for Naver Cloud's data center located in Goyang City.
Sources: placements without a source URL come from the taxonomy seed and are tagged accordingly. How this data is built.· Markdown · JSON