Who makes ups (static, modular, rotary/drups) & ups power semis for AI data centers

Uninterruptible power supplies that bridge the gap between a utility outage and generator start, built as static (battery-based), modular, or rotary/diesel-rotary (DRUPS) designs, plus the power semiconductors inside them.

UPS sits between LV switchgear (7.05) and the IT load, holding output voltage steady through the brief gap between a utility interruption and the moment backup generators (7.13) come online and take over. Static UPS units use battery energy storage (7.11) and power electronics to do this; rotary and diesel-rotary UPS (DRUPS) use spinning mass and, in the DRUPS case, an integrated engine to bridge the same gap without a separate battery bank; modular UPS lets capacity be added in smaller increments as a facility grows. Inside a static UPS, IGBT and silicon-carbide power semiconductor modules do the actual power conversion between AC, DC, and back to AC, and the performance and efficiency of a UPS increasingly depends on those semiconductor choices as much as on the battery or rotary system around them. Beyond simple outage bridging, AI clusters draw power in sharp, correlated swings as large synchronized GPU jobs start, stop, or checkpoint, and utilities and grid operators are increasingly asking data centers to use UPS and related equipment (7.12) to smooth those swings rather than let them propagate onto the grid. For investors, watch UPS order backlogs, capacity additions among the small set of vendors building at data-center scale, and how much of the value is migrating toward the power semiconductor content inside each unit.

AI delta: GPU cluster power draw swings sharply and quickly with training and inference workload changes, and UPS systems are increasingly being asked to absorb those swings for grid stability rather than just bridge outages.

Appears at:Enterprise / small coloLarge colo / hyperscale buildingAI campusGW-class campus· cooling:any — Present at every scale; the architecture shifts from a handful of large static UPS at hyperscale and above toward more distributed or rotary designs depending on site design choices.

Companies on this part (18)

CompanyRoleOwnershipTickerPrice1dConfidenceNote
ABBmanufacturerpublicABBN.SW79.28 CHF-0.6%inferred
Cyber Powermanufacturerpublic3617.TW245 TWD-1.4%inferred
Delta Electronicsmanufacturerpublic2308.TW1800 TWD+2.0%inferred
EatonmanufacturerpublicETN416 USD-2.3%inferred
Fuji Electricmanufacturerpublic6504.T14105 JPY-1.1%inferred
Kehuamanufacturerpublic002335.SZ31.57 CNY+2.4%inferred
LegrandmanufacturerpublicLR.PA136 EUR-0.8%inferred
Mitsubishi Electricmanufacturerpublic6503.T5641 JPY+1.0%inferred
Schneider ElectricmanufacturerpublicSU.PA298 EUR-0.6%inferred
VertivmanufacturerpublicVRT269 USD-1.5%inferred
Centielmanufacturerprivateinferred
HitecmanufacturerprivateinferredDRUPS
Huaweimanufacturerprivateinferred
Pillermanufacturerprivateinferredrotary
Rehlko (Kohler Energy)manufacturerprivateinferred
Riellomanufacturerprivateinferred
Socomecmanufacturerprivateinferred
Toshibamanufacturerprivateinferred

IGBT and SiC modules 7.10a

CompanyRoleOwnershipTickerPrice1dConfidenceNote
Fuji Electricmanufacturerpublic6504.T14105 JPY-1.1%inferred
InfineonmanufacturerpublicIFX.DE57.17 EUR+3.6%inferred
Mitsubishi Electricmanufacturerpublic6503.T5641 JPY+1.0%inferred
onsemimanufacturerpublicON74.80 USD+0.2%inferred
WolfspeedmanufacturerpublicWOLF26.95 USD-3.1%inferred
Semikron Danfossmanufacturerprivateinferred

Who competes here

The same table read the other way: every company above competes for ups (static, modular, rotary/drups) & ups power semis sockets. Confidence tags matter — an inferred placement is a lead, not a confirmed rivalry.

Nearby parts

Watch

How Data Center UPS Systems Work
MEP Academy — UPS topologies and role in data center power resilience
Click to load from YouTube · open on YouTube ↗

Independent videos — no affiliation; nothing loads from YouTube until you click.

Latest feed

Sources: placements without a source URL come from the taxonomy seed and are tagged accordingly. How this data is builtMarkdown · JSON