Who makes floor PDUs for AI data centers

Floor-mounted power distribution units, remote power panels, and the static and automatic transfer switches that route power between utility, UPS, and generator sources down to the rack level.

Floor PDUs and RPPs are the last stage of building-level distribution before power reaches busway or in-rack distribution, stepping down and metering power for a zone of racks. Static transfer switches (STS) and automatic transfer switches (ATS) sit alongside them to switch a load between sources — typically utility and UPS-backed paths, or normal and generator power — without an interruption the IT equipment would notice, which is what lets a facility carry dual, concurrently maintainable power paths. As rack power draw rises, floor PDUs and RPPs are being specified at higher ampacity, and the distance between a PDU and the racks it serves is shrinking, because running high current over long low-voltage cable runs loses more power as heat than moving that distribution closer to the load. This equipment overlaps with UPS and generator suppliers (7.10, 7.13), since transfer switching logic has to be engineered together with those systems rather than sourced independently. For investors, useful signals are how fast vendors are qualifying higher-ampacity PDU and STS product lines for AI-density halls, and whether facilities are standardizing on fewer, larger PDUs per zone versus more numerous smaller units, which changes the addressable unit count per campus.

AI delta: Higher rack power draw is pushing floor PDU and RPP ratings up and shortening the distance these units sit from the rack, since longer low-voltage runs at high current become less efficient.

Appears at:Enterprise / small coloLarge colo / hyperscale buildingAI campusGW-class campus· cooling:any — Present at every scale; unit count and ampacity per zone scale with hall density.

Companies on this part (12)

CompanyRoleOwnershipTickerPrice1dConfidenceNote
ABBmanufacturerpublicABBN.SW67.78 CHF-1.2%inferred
CaterpillarmanufacturerpublicCAT687 USD-2.3%inferred
CumminsmanufacturerpublicCMI517 USD+0.5%inferred
Delta Electronicsmanufacturerpublic2308.TW1560 TWD-3.4%disclosed · source
EatonmanufacturerpublicETN366 USD-1.7%inferred
GeneracmanufacturerpublicGNRC187 USD-1.1%inferred
LegrandmanufacturerpublicLR.PA124 EUR+0.4%inferred
Russelectric · unit of SiemensmanufacturersubsidiarySIE.DE*inferred
Schneider ElectricmanufacturerpublicSU.PA231 EUR-1.4%inferred
VertivmanufacturerpublicVRT194 USD-0.2%inferredPDI
PillermanufacturerprivateinferredLangley
Rehlko (Kohler Energy)manufacturerprivateinferred

Who competes here

The same table read the other way: every company above competes for floor PDUs, RPPs, static transfer switches, ATS sockets. Confidence tags matter — an inferred placement is a lead, not a confirmed rivalry.

Nearby parts

From the blog

Watch

Automatic transfer switch (ATS) fundamentals | Eaton PSEC
Eaton — ATS operation for shifting critical loads between power sources
Click to load from YouTube · open on YouTube ↗

Independent videos — no affiliation; nothing loads from YouTube until you click.

Latest feed

Questions about floor PDUs, RPPs, static transfer switches, ATS

What are floor PDUs, RPPs, static transfer switches, ATS?
Floor-mounted power distribution units, remote power panels, and the static and automatic transfer switches that route power between utility, UPS, and generator sources down to the rack level.
Which companies make floor PDUs for AI data centers?
This catalog lists 12 companies on Floor PDUs, RPPs, static transfer switches, ATS, 10 of them with listed equity: ABB, Caterpillar, Cummins, Delta Electronics, Eaton, Generac, Legrand, Russelectric, Schneider Electric, Vertiv, and 2 more.
How does AI change demand for floor PDUs, RPPs, static transfer switches, ATS?
Higher rack power draw is pushing floor PDU and RPP ratings up and shortening the distance these units sit from the rack, since longer low-voltage runs at high current become less efficient.
How reliable are these floor PDUs, RPPs, static transfer switches, ATS supplier placements?
The 12 placements on this part break down as 1 disclosed, 11 inferred. "disclosed" means the company or a filing says so; "reported" comes from trade press or a reference-design list; "inferred" is a taxonomy lead with no citation yet.

Sources: placements without a source URL come from the taxonomy seed and are tagged accordingly. How this data is built.· Markdown · JSON