CoolIT vs nVent
CoolIT and nVent are both placed on 3 of the same AI data center parts in this catalog, spanning layer 5. CoolIT appears on 4 parts in total and nVent on 9.
At a glance
| CoolIT | nVent | |
|---|---|---|
| Ownership | private | public |
| Headquarters | not on file | London, United Kingdom |
| Primary listing | none in catalog | NVT |
| Market cap | 20.3B USD | |
| Parts placed | 4 | 9 |
| Layers covered | 1 | 3 |
| Units / subsidiaries | 0 | 0 |
| Seen in machines | 1 | 1 |
Market caps are a nightly snapshot in each listing's own currency, never converted.
What the shared parts are
- Rack manifolds — The manifold (sometimes called a CDM) that distributes coolant from the CDU supply line to each cold plate in a rack and collects the return flow, usually mounted vertically at the rear or side of the rack.
- Coolant distribution units — The unit that separates the IT-side (technology) coolant loop from the facility water loop, exchanging heat between them and pumping and filtering the technology-side flow — sized from in-rack and in-row units up to multi-megawatt facility-class units.
- Rack/row cooling controls & software — Software and controllers that manage coolant setpoints, pump speed, and valve positions at the rack and row level, and that tie into facility-wide data center infrastructure management (DCIM) systems.
The 3 parts both make
| Part | CoolIT | nVent |
|---|---|---|
| Rack manifolds Layer 5 — Liquid cooling (IT-side: chip to CDU) | manufacturer disclosed | manufacturer disclosed |
| Coolant distribution units Layer 5 — Liquid cooling (IT-side: chip to CDU) | manufacturer inferred | manufacturer inferred |
| Rack/row cooling controls & software Layer 5 — Liquid cooling (IT-side: chip to CDU) | manufacturer inferred | manufacturer inferred |
Only CoolIT
- Direct-to-chip cold plates layer 5
Only nVent
- Rack PDUs layer 4
- Rear-door heat exchangers layer 5
- Leak detection, flow & pressure sensing layer 5
- Circuit protection, fuses, surge, grounding layer 7
- Enclosures layer 4
- Tray and supports layer 7
Named in the same machines
- Nvidia GB300 NVL72 rack teardown
Questions
- Do CoolIT and nVent compete?
- In this catalog they are both placed on 3 of the same parts, across 1 layer: Rack manifolds, Coolant distribution units, Rack/row cooling controls & software. Sharing a part does not mean selling the same product to the same buyer, so read each row's product note.
- Which has more placements, CoolIT or nVent?
- CoolIT has 4 placements and nVent has 9. Placement counts reflect how thoroughly each company has been catalogued as well as its real breadth, so they are not a ranking.