What Kelvion makes for data centers
private · kelvion.com
Kelvion is a private company. It appears on 4 parts of the AI data center — CDU internals: plate heat exchangers, pumps, filters, Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors, Heat reuse & district heating interfaces and Plate HX — in the role of manufacturer. Those parts sit in Layer 5 — Liquid cooling (IT-side: chip to CDU) and Layer 6 — Facility cooling & HVAC.
Parts, by layer
Layer 5 — Liquid cooling (IT-side: chip to CDU)
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| CDU internals: plate heat exchangers, pumps, filters | manufacturer | disclosed | Alfa Laval, Kaori, Danfoss, SWEP |
Layer 6 — Facility cooling & HVAC
| Part | Role | Confidence | Competitors | Note |
|---|---|---|---|---|
| Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors | manufacturer | inferred | Alfa Laval, Daikin, LU-VE, Modine, Munters, SPX Technologies | |
| Heat reuse & district heating interfaces | manufacturer | disclosed | Alfa Laval, Carrier, Fortum, Siemens Energy, Trane, Danfoss | |
| Plate HX | manufacturer | disclosed | Alfa Laval, Danfoss, SWEP |
Where Kelvion sits in the stack
Kelvion's placements in this catalog cover 4 parts, from layer 5 (liquid cooling (it-side: chip to cdu)) to layer 6 (facility cooling & hvac). None of them currently carries a sourced supply constraint tag. Across these parts it overlaps with other companies most often on the lines below.
What these parts are
- CDU internals: plate heat exchangers, pumps, filters — The internal components of a CDU — plate heat exchangers, pumps, and filters — that do the actual heat exchange, circulation, and particulate control inside the unit.
- Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors — Dry coolers, adiabatic/evaporative units, and cooling towers reject heat picked up by the facility water loop to outside air, driven by fans and motors.
- Plate HX — Plate heat exchangers that isolate one water loop from another — for example, the facility loop from the IT-side loop — so a leak or pressure event on one side doesn't cross into the other.
- Heat reuse & district heating interfaces — Heat exchangers and interconnection equipment that export waste heat from a data center's cooling loop into a district heating network or other end use instead of rejecting it to atmosphere.
Closest peers in this catalog
Questions about Kelvion
- What does Kelvion make for AI data centers?
- This catalog places Kelvion on 4 parts: CDU internals: plate heat exchangers, pumps, filters (manufacturer), Dry coolers, adiabatic/evaporative units, cooling towers, fans & motors (manufacturer), Heat reuse & district heating interfaces (manufacturer) and Plate HX (manufacturer).
- Is Kelvion publicly traded?
- No listing is on file for Kelvion in this catalog; it is recorded as private.
- Who else makes CDU internals: plate heat exchangers, pumps, filters for AI data centers?
- Alfa Laval, Kaori, Danfoss and SWEP are also placed on CDU internals: plate heat exchangers, pumps, filters in this catalog.
- How well sourced are these placements?
- Every part→company placement carries a confidence tag. For Kelvion the mix is 3 disclosed and 1 inferred. "disclosed" means the company or a filing says so; "reported" comes from trade press or a reference-design list; "inferred" is a lead from the taxonomy with no citation yet. Treat reported and inferred as leads, not facts.
Answers are generated from this catalog's own rows — see sources & method.