Who makes plate HX for AI data centers
Plate heat exchangers that isolate one water loop from another — for example, the facility loop from the IT-side loop — so a leak or pressure event on one side doesn't cross into the other.
A plate heat exchanger transfers heat between two water loops without letting them mix. Corrugated plates stack with alternating channels, one loop on each side, and the design gets a large surface area into a small volume — which is why this is how the facility loop and the technology loop meet in almost every liquid-cooled deployment. Keeping the loops separate is the entire point. The facility loop is building water: treated, but shared with equipment across the site and subject to whatever the plant does. The technology loop runs through cold plates with narrow channels and touches the accelerators. Letting one into the other would put the site's water chemistry, its particulate, and its pressure transients into the hardware. The exchanger also decouples pressure, so a fault on the facility side cannot overpressure the delicate side. Exchangers come gasketed, which can be opened and cleaned, or brazed, which cannot but has no gasket to fail. The choice is a maintenance philosophy. What to look for is the approach temperature — how close the two loops get, which directly sets how warm the facility loop must run and therefore how much free cooling the site can use — and whether the unit is bought standalone or inside a CDU, since the same component appears in both places in this catalog.
Companies on this part (4)
| Company | Role | Ownership | Ticker | Price | 1d | Confidence | Note |
|---|---|---|---|---|---|---|---|
| Alfa Laval | manufacturer | public | ALFA.ST | 540 SEK | -0.2% | disclosed | · source |
| SWEP · unit of Dover | manufacturer | subsidiary | DOV* | inferred | with Dover | ||
| Danfoss | manufacturer | private | inferred | ||||
| Kelvion | manufacturer | private | disclosed | · source |
Who competes here
The same table read the other way: every company above competes for plate HX sockets. Confidence tags matter — an inferred placement is a lead, not a confirmed rivalry.
Nearby parts
- Parent: Facility water loop hardware
- Previous in layer: Air handling, economizers, filtration
- Next in layer: Water treatment, reuse, consumption
- Layer: Layer 6 — Facility cooling & HVAC
Questions about plate HX
- What is plate HX?
- Plate heat exchangers that isolate one water loop from another — for example, the facility loop from the IT-side loop — so a leak or pressure event on one side doesn't cross into the other.
- Which companies make plate HX for AI data centers?
- This catalog lists 4 companies on Plate HX, 2 of them with listed equity: Alfa Laval, SWEP, Danfoss, Kelvion.
- How reliable are these plate HX supplier placements?
- The 4 placements on this part break down as 2 disclosed, 2 inferred. "disclosed" means the company or a filing says so; "reported" comes from trade press or a reference-design list; "inferred" is a taxonomy lead with no citation yet.
Sources: placements without a source URL come from the taxonomy seed and are tagged accordingly. How this data is built.· Markdown · JSON